H2PrismHydrogen intelligenceSubscribe

All insights

Analysis · 2 min read

Fuel cell CHP efficiency: electricity, useful heat and the numbers that matter

A high combined efficiency depends on heat that the customer can actually use, measured on a stated fuel-energy basis.

Two efficiencies, two questions

The U.S. Department of Energy defines the CHP energy efficiency in these tables as regulated AC net output energy plus recovered thermal energy, divided by the lower heating value of the input fuel. Counted heat must be hot enough for space and water heating. The table recommends heat at 80 degrees C or higher.

Sources
  1. [1] U.S. Department of Energy: DOE Technical Targets for Fuel Cell Systems for Stationary (Combined Heat and Power) Applications

    Last confirmed: 16 Nov 2026

A historical reference, not a product guarantee

For natural-gas systems of 1 to 25 kilowatts electrical output in residential and light commercial service, the DOE table lists a 2015 status electrical efficiency at rated power of 34-40 percent and a CHP energy efficiency of 80-90 percent, both on an LHV basis. Electrical efficiency here is regulated AC net output divided by fuel LHV.

Sources
  1. [1] U.S. Department of Energy: DOE Technical Targets for Fuel Cell Systems for Stationary (Combined Heat and Power) Applications

    Last confirmed: 16 Nov 2026

Why heat demand changes the answer

The combined number is useful only if the site can absorb the recovered heat when it is produced and at the temperature required. A building with a year-round hot-water load may be able to use more heat than one with a seasonal heating load. If heat cannot be used, the useful energy delivered to the customer falls. Ask suppliers to show electrical output and usable heat separately, alongside the assumed operating schedule.

Sources
  1. [1] U.S. Department of Energy: DOE Technical Targets for Fuel Cell Systems for Stationary (Combined Heat and Power) Applications

    Last confirmed: 16 Nov 2026

Comparing proposals

Compare the same fuel and heating-value convention, net rather than gross electrical output, heat temperature, and the system boundary. Check whether auxiliary equipment and heat exchange are included and whether figures apply at rated load or across the expected operating profile. Ask for fuel consumption and maintenance assumptions as well. A single combined percentage cannot establish a site's annual energy savings or cost.

Sources
  1. [1] U.S. Department of Energy: DOE Technical Targets for Fuel Cell Systems for Stationary (Combined Heat and Power) Applications

    Last confirmed: 16 Nov 2026

Related analyses

Explore related records

Research method

Research and writing were AI-assisted and reviewed before publication.